The main disadvantage of the translational sprinkler is that the whole machine can only move in a straight line along the direction of the vertical branch pipe, but can not move along the longitudinal direction,adjacent towers can not rotate between.For this reason, the translational sprinkler must have guiding equipment in operation.In addition, the central tower of the translational sprinkler is constantly moving,so the position of the water intake point is constantly changing.The usual method is to take water from open channels and drag away the hose supply. Farm Irrigation Sprinkler,Farm Watering System,Remote Irrigation Machine,Large Farm Irrigation Systems Shandong H.T-BAUER Water and Agricultural Machinery & Engineering Co., Ltd. , https://www.ht-bauer.com
1. The chiller adopt high-quality compressor and Italy pump, so it is very sate and noiseless, economical in power and durable
2. The chiller is deployed with Italy temperature controller, it can control the temperature between 3 and 35 degrees exactly
3. The designs of chiller and radiator are unique, so the heat exchange efficiency is very high
4. The chiller is designed to be with current over-load protector, high voltage and low voltage construction and electric time-delay safeguard, when malfunction happened, it could alarm and show the cause of the problem in time.
5. It has stainless steel temperature-holder box, it is very convince to purify
6. It is designed to be with anti-phase & lack-phase protector and anti-icy protector
7. The temperature of ultra cod chiller can be below -15 degrees.
8. This series chiller can customize base on the requirement of acid resistant & acidity-resistant
9. It has got CE certification.
                                                                                                                            Industrial Air-cooled Water  Chiller
       Model      HLLA~
03S
05S
08S
10S
12.5S
15S
20D
25D
30D
40T
45T
Rated Cooling Capacity× 1000kcal/h
6.8
11.1
17.3
23.4
27.1
34
46.8
54.2
68.1
81.3
102.1
KW
7.9
12.9
20.1
27.2
31.5
39.6
54.5
63.0
79.2
94.5
118.8
  lnput power (KW)
3.02
4.62
6.75
8.7
9.8
13.8
17.4
19.6
27.6
29.4
41.4
 ×  Comp.  lnput Power× Qty (KW)
2.5× 1
4.1× 1
6.1× 1
7.5× 1
8.6× 1
11.8× 1
7.5× 2
8.6× 2
11.8× 2
8.6× 3
11.8× 3
 Comp.  Current (A)
5.7
9.2
13.5
17.6
19.3
26.7
35.2
38.6
53.4
57.9
80.1
 RefrigerantÂ
 R22
  Power SupplyÂ
440V/Â 3ph/Â 60Hz
 Safety Protection
, Â , Â , Â , Â , Â , Â
Phase reversion protection,  Phase lack protection,  Overload current protection,
Discharge air temp.   protection,  Low &  High pressure protection,  Hi/ Low temp.   protection,  Water flow protection.
  Number of Refrigeration Circuit
1
2
3
 Capacity Control (%)
0, Â 100
0, Â 50, Â 100Â Â Â Â Â Â Â Â Â Â
 0,  33,  66,  100
 Condenser
                 Ripple Aluminum Fins around Copper Pipe
  Power lnput of Fan (KW)
0.52
0.52
0.65
1.2
1.2
2
2.4
2.4
4.0
3.6
6.0
 Evaporator
 Shell and Tube Type
 Water Side Max Pressure (MPa)
1
  Dia. of Pipe to Evaporator (inch)
1-1/2"
1-1/2"
1-1/2"
1-1/2"
2"
2"
2"
2"
2-1/2"
2-1/2"
2-1/2"
  Chilled Water Flow (L/m)
23
37
58
78
90
113
156
181
227
271
340
 Evaporator Water Pressure drop (kPa)
13
14
17
23
28
30
28
28
32
32
31
 Running Noise dB(A)
72
72
73
75
75
75
75
75
75
75
75
 Total weight (kg)
130
170
370
400
450
540
760
800
1000
1200
1400
Model NO.: HLLA-03SI~45TI
Application Fields: Chemical
Application Machine: Machining Center
Certification: CE
Condition: New
Cooling Capacity: 7.9kw-118.8kw
Refrigerant: R22, R407c
Power Supply: 380V-3-pH-50Hz
Evaporator: Shell and Tube Type
Power Input: 3.85kw
Compressor Type: Scroll Type
Power Source: Electrical
Noise Db(a): 72
Chilled Water Flow: 26.4m3/H
Trademark: Golden
Specification: CE
Origin: Dongguan, Guangdong
HS Code: 8418692090
Hot Selling Package Industrial Air Cooled Water Chiller